Enter your Email address below and press the GO button.
Inteli-Power 4600 Series models can recharge the battery to 90% in 2-3 hours using our patented Charge Wizard technology.
The built-in Charge Wizard automatically selects one of four operating modes: BOOST, NORMAL, STORAGE, DESULFATION.
BOOST Mode 14.4 Volts - Rapidly brings RV battery up to 90% of full charge.
NORMAL Mode 13.6 Volts - Safely completes the charge.
STORAGE Mode 13.2 Volts - Maintains charge with minimal gassing or water loss.
DESULFATION Mode 14.4 Volts every 21 hours for a period of 15 minutes to prevent battery stratification.
WHAT IS THE CHARGE WIZARD?
The Charge Wizard is a microprocessor-controlled device designed to operate with all Inteli-Power Converters. It constantly monitors the RV battery, then automatically adjusts the converter output voltage based on its charge status. The Charge Wizard has four (4) operating Modes (BOOST, NORMAL, STORAGE AND DESULFATION/EQUALIZE). Each Mode is automatically selected by the microprocessor and ensures a fast yet safe recharge for your RV batteries.
CHARGE WIZARD INDICATOR
The included fuse board has a light that indicates the Mode that the Charge Wizard is operating in as follows.
LIGHT “ON” AT ALL TIMES – Indicates the Charge Wizard is in the Boost Mode (Converter output voltage set to 14.4-volts)
LIGHT “BLINKS” ON AND OFF APPROX. EVERY SECOND. – The Charge Wizard is in the Normal Mode (Converter output voltage set to 13.6-volts).
LIGHT “BLINKS” ON AND OFF APPROX. EVERY 5 SECONDS. – The Charge Wizard is in the Storage Mode (Converter output voltage set to 13.2-volts).
THE MODE SELECT SWITCH
The Charge Wizard functions are fully automatic however; you can test the Charge Wizard’s functions manually by pressing and holding the MODE SELECT SWITCH BUTTON DOWN. When the button is first pressed, the light will be “ON” all the time, indicating it is in the BOOST Mode (converter output 14.4 VDC). If you continue to hold the button, the unit will switch to the NORMAL Mode (converter output 13.6 VDC) and the light will blink approximately once a second. If you continue to hold the button down the unit will go into the STORAGE Mode (converter output 13.2 VDC) and the light will blink approximately every five- (5) seconds. NOTE: No matter which mode you manually select, the Charge Wizard will automatically return to the NORMAL Mode of operation after 4 -hours.
BATTERY RECHARGE CURVESWITH CONVERTER OUTPUT VOLTAGE SET AT 14.4, 13.6 AND 13.2-VOLTS