UMPFC-1
Universal Igniter Board with Fan Control Features:
• Fuse protection
• Remote flame sense
• 3-try fire routine
• 20 sec fire delay with 20 second purge between fire cycles
• BI-color LED, Green when board is powered, Red when gas valve is energized, Flashing Green when 3-tries have occurred with no flame
• Checks for shorted electrode prior to firing. If electrode is shorted board will not fire and will continually flash LED Green 5 times.
• Fan Control Model protects battery in the event flame out occurs.